Electromyography (EMG) measures the muscle response or electrical activity by way of a nerve’s stimulation of the muscle. In particular, Surface EMG signals are recorded by non-invasive electrodes on the surface of the skin above the muscle to assess muscle function and understand how well the brain and musculoskeletal system are coordinated. Surface EMG is an important part of physiology and biomechanics research and has also been developed as a useful evaluation tool for rehabilitation, sports performance, and ergonomics. Determining the most appropriate system for your individual requirements can be challenging, so it is important to carefully consider your unique needs when choosing between the Core or Ultium EMG systems.

Key Comparisons

Sensor

  • Li-Ion coin cell battery
  • 4-houroperational runtime
  • 3-hour charge time

Receiver

  • Power and data transfer by USB-C
  • Accepts 2-5 V TTL sync input
  • 2.4 GHz wireless and Bluetooth Low Energy
  • 30 m wireless transmission range
  • 1 Gigabit onboard memory (up to 8 hours of storage)
  • High-speed data transfer via sensor dock
  • 2000 Hz sample rate
  • 20 Hz high-pass cutoff
  • 500 Hz low-pass cutoff
  • No notch (50/60 Hz) filters
  • ± 24,000 µV input range
  • 24-bit ADC with dynamic resolution
  • < 2 µV RMS baseline noise
  • > 90 dB CMRR

Sensor

  • 42 x 30 x 12.5 mm (LxWxH)
  • 15 g

Receiver

  • 170 x 60 x 113 mm (LxWxH)
  • 145 g
  • Captures EMG data only
  • Direct Connect design for convenience
  • Supports up to 4 Core EMG sensors
    • Not compatible with Ultium SmartLeads
  • System includes sensors and hub

Sensor

  • Li-Polymer battery
  • 8-hour operational runtime
  • 3-hour charge time

Receiver

  • Power and data transfer by USB
  • Sensor charging by 5V PSU
  • Accepts 2-5 V TTL sync input
  • 2.4 GHz wireless and Bluetooth Low Energy
  • 30 m wireless transmission range
  • Analog output with adjustable gain and fixed 300 ms latency
  • 2 Gigabit onboard memory (up to 16 hours of storage)
  • High-speed data transfer via sensor dock
  • Selectable sample rate at 2000 or 4000 Hz
  • Selectable high-pass cutoff at 5/10/20 Hz
  • Selectable low-pass cutoff at 500/1000/1500 Hz
  • No notch (50/60 Hz) filters
  • ± 24,000 µV input range
  • 24-bit ADC with dynamic resolution 
  • < 1 µV RMS baseline noise
  • > 100 dB CMRR

Sensor

  • 37 x 24.5 x 16.5 mm (LxWxH)
  • 14 g

Receiver

  • 174 x 92 x 169 mm (LxWxH)
  • 545 g

Charger

  • 261 x 36 x 29 mm (LxWxH)
  • 185 g
  • Captures EMG + integrated IMU data
  • Detachable lead design for versatility
  • Supports up to 16 Ultium sensors
    • Compatible with Ultium EMG, SmartLeads, and Ultium Motion
  • System includes sensors, receiver, and charger(s)