EMG

Clarity and reliability that always exceeds expectations,
any way you want to measure it.

Learn More About EMG

Why Noraxon

Innovation demands our best performance, each and every day. We’ve purposefully aligned our focus on innovation with your commitment to excellence, assuring you can study human movement with confidence. Capture precise data with stability and speed, process more records with ease, and utilize innovative technology with unprecedented simplicity. Choose Noraxon first.

Trusted

Trusted

For nearly 4 decades our team has been committed to engineering excellence. This has translated into a level of trust that makes our EMG systems the most widely used tool of the the trade.

Applications

Applications

Noraxon EMG systems are ideal for university research, clinical, sports science, ergonomic, hospital and all human performance applications.

Modular & Mobile

Modular & Mobile

Whether in the lab or on the field, our precise and reliable modular approach allows you to capture the movement data you need in the environment you want.

Patented Inventions

Patented Inventions

At the heart of all Noraxon systems is patented and FDA-approved technology that powers our world-class data capture systems. The result is reliable, repeatable and pure data that enables precise study of human movement.

Signal Integrity

Signal Integrity

For decades, Noraxon has led the market with an unmatched level of signal clarity, resulting in artifact- and noise-free data. Our patneted myoSURE amplifier technology is at the heart of this innovation.

Fully Integrated Platform

Fully Integrated Platform

Our EMG data collection and analysis software module is called myoMUSCLE.™ It’s part of the myoRESEARCH software suite, which offers fully integrated and synchronized, highly precise data across all protocols, so you have a comprehensive view of human movement.

“The new generation of scientists are trying to move away from traditional lab based science. Life happens outside of the lab, and Noraxon’s reliable wireless EMG allows me to collect this historically difficult to acquire data.”

Harsimran S Baweja P.T. Ph.D.
SDSU Center for Clinical and Cognitive Neuroscience

Products

Wireless. Precise. Simple. Fast. Functional. Measure your way.

Ultium™ ESP

  • 2000/4000 Hz raw EMG
  • Up to 16 channels EMG
  • Highest Fidelity Data (24-bit)
  • <1 µV Baseline Noise Levels (Static and Dynamic)
  • Multi-purpose sensors  (Featuring SmartLeads with auto-detection)
  • Built-in impedance checker and Battery status
  • Find-My-Sensor visual feedback

Ultium™ ESP Specifications

EMG Sampling rateUp to 4,000 Hz
Internal Sampling Resolution24-bit
Baseline noise<1μV
CMRR< -100dB
Internal Memory>8 hours of data logging
Analog OutputUp to 32 channels available

Mini DTS

  • 1500 / 3000 Hz raw EMG
  • Wireless, compact sensors are fast and easy to set up
  • EMG signal is unprocessed, ready for advanced EMG analysis
  • 4 -channel configuration, 8 hours operation on battery charge
  • Portable USB-powered receiver
  • Combine 2 Mini DTS receivers for up to 8-channel EMG collections
  • Real time transmission up to 20 meters
  • Sync with myoVIDEO and myoPRESSURE for gait analysis

Mini DTS Specifications

WirelessYES
Sample Rate1500, 3000
Resolution16 bits
Channels4
Gain500
CMRR> 100dB
Input Impedance> 100Mohm
Baseline Noise< 1uVRMS
EMG Sensor Size3.4cm (L) x 2.4cm (W) x 1.4cm (H)
Receiver Size7.66cm (L) x 10.18cm (W) x 3.55 (H)

Clinical DTS

  • 100 Hz of RMS EMG
  • 2, 4 or 8-channel configuration, 8 hours operation on battery charge
  • EMG signal is pre-processed and ready to use
  • Wireless, compact sensors are fast and easy to set up
  • Bluetooth enabled for Android
  • Portable USB powered receiver
  • Real time transmission up to 20 meters
  • Sync with myoVIDEO and myoPRESSURE for gait analysis

Clinical DTS Specifications

Sample Rate100Hz (RMS EMG Waveforms)
WirelessYES
Resolution16 bits
Channels8
Gain500
CMRR> 100dB
Input Impedance> 100Mohm
EMG Sensor Size
  • 1.34"L x 0.95"W x .55"H
  • 3.4cm x 2.4cm x 1.4cm
EMG Sensor Weight
  • 0.5 oz
  • 14 grams

Seamlessly integrated into myoRESEARCH®

The ultimate biomechanics analysis software platform

Learn More About myoRESEARCH

Noraxon EMG software module: myoMUSCLE

Receive and analyze biofeedback from EMG and other sensors attached to the body while movement is in progress.

Sensors

Wireless

Muscle Dynamometer Wireless

Muscle Dynamometer Wireless

Handheld/portable force dynamometer that measures tension and compression forces. Can be used stand alone or synchronized with a DTS universal analog input probe.

Flexiforce Local Pressure Wireless

Flexiforce Local Pressure Wireless

Very thin and flexible sensor construction allow for the measurement of pressure force between body and external surfaces, tools or machines.

BioMonitor Wireless

BioMonitor Wireless

Cardiorespiratory sensor that simultaneously measure 6 channels of data:
– Respiration
– ECG
– Respiratory Rate
– Heart Rate
– R/R Interval
– Temperature

Footswitch Insoles Wireless

Footswitch Insoles Wireless

Set comes with 2 DTS probes and 2 insoles for bilateral gait analysis. Provides up to 4 quadrants per foot.

Accelerometer Wireless

Accelerometer Wireless

Scaling available in:
– 2G/6G
– 24G
– 100G/400G
Measures acceleration forces and vibration in 3 dimensions (measured in G’s)

Footswitch FSRs Wireless

Footswitch FSRs Wireless

Comes with a set of DTS probes and a set of 4 small footswitch sensors per foot, per side. Capable of marking heel strike and toe-off events during gait with adjustable sensitivity.

Inline

Muscle Dynamometer Inline

Muscle Dynamometer Inline

Handheld/portable force dynamometer that measures tension and compression forces. Can be used stand alone or synchronized with a myoTrace 400.

2D Inclinometer Inline

2D Inclinometer Inline

Measures range of motion in 1D or 2D. Can be used for the spine and extremities or mounted on training machines.

Mechanical Goniometer Inline

Mechanical Goniometer Inline

Measures angular displacementin 1 axis. Gliding mechanism and flexible arms compensates for axis motion and uneven surfaces.

Flexiforce Local Pressure Inline

Flexiforce Local Pressure Inline

Very thin and flexible sensor construction allow for the measurement of pressure force between body and external surfaces, tools or machines.

Footswitch FSRs Inline

Footswitch FSRs Inline

Comes with a set of 4 small footswitch sensors per foot, per side. Capable of marking heel strike and toe-off events during gait with adjustable sensitivity.

Footswitch Insoles Inline

Footswitch Insoles Inline

Set comes with 2 insoles for bilateral gait analysis. Provides up to 4 quadrants per foot.

Accelerometer Inline

Accelerometer Inline

Scaling available in:
– 2G/6G
– 16G
Measures acceleration forces and vibration in 3 dimensions (measured in G’s)