Introducing the Ultium™ Biomechanics Research System

With the world’s best EMG technology at its core, the Ultium-ESP sensor system is a multi-modal, wireless electronic signal portal. The full-featured ESP sensor samples up to 4,000 times per second, synchronizes in real-time, and demonstrates the lowest baseline noise with the fewest native artifacts of any similar technology.

Sophisticated advances in technology resulted in the patent-pending “SmartLead” system, which transforms the ESP device into an intelligent sensor that delivers virtually any type of biometric and physiological data, from any type of hardware, with the flexibility to accurately capture the most interesting aspects of human movement.

Applications

Symmetry & Coordination Tests

Symmetry & Coordination Tests

These various tests allow for the comparison of affected and unaffected sides. Display the EMG and histogram statistics for unilateral, bilateral, multi joint and symmetrical movements. Evaluate the neuromuscular coordination and compare innervation deficiencies between right and left sides.

Average Activation Patterns

Average Activation Patterns

Assess repeated movement sequences and exercises while creating averaged and time normalized EMG patterns. Analyze the typical innervation structure of movements.

EMG Standard Analysis

EMG Standard Analysis

The new Ultium-ESP uses a universal protocol for all kinds of EMG setups. View basic amplitude parameters in selected analysis periods. Use standard graphs and histograms designed for general analysis questions.

Feedback Training

Feedback Training

Use the bar graph display of signals to provide precise training of dysfunctional muscle groups with both acoustic and optical automatic training assistance.

Gait Analysis

Gait Analysis

The protocol for this analysis was designed for unilateral and bilateral investigation of EMG gait patterns in functional walking and running activities. View typical activity characteristics and coordination of muscle groups during walking/running while analyzing left/right, pre/post test comparisons.

Template Training

Template Training

Use background templates for biofeedback training. Create EMG/angle/force templates using the healthy side. Use biofeedback and motor learning concepts to confirm the accuracy of performance.

Patented Innovations

At the heart of Noraxon’s biomechanics platform are patented and FDA-approved technologies that power world-class
data capture. The result is reliable, repeatable and pure data that enables the precise study of human movement.

Technical Specifications

EMG Sampling rateUp to 4,000 Hz
Internal Sampling Resolution24-bit
Baseline noise<1μV
CMRR< -100dB
Internal Memory>8 hours of data logging
Analog OutputUp to 32 channels available

Four decades of EMG expertise.

Clarity and reliability that always meets expectations, any way you measure it.

Noraxon EMG Software Module: myoMUSCLETM

The myoMUSCLE™ software module features an intricate and sophisticated toolset capable of handling any type of electro-kinesiological data captured with the Ultium-ESP sensors. Real-time data is automatically synchronized in an all-in-one analysis, enabling detailed insight for performance enhancement, injury recovery or research metrics. Multiple data export formats and HTTP streaming also allow compatibility with third-party research and animation programs.

The Ultium-ESP Sensor

ULTIUM-ESP SENSOR DIMENSIONS
Size: 37 x 24.5 x 16.5 mm (LxWxH)
Weight: 14 grams

TECHNICAL DATA

OUTPUT AND TRANSMISSION FREQUENCY

  •  up to 100 mW
  • 30-meter sensor transmission range
  • Proprietary radio frequency hopping protocol
  • 2402-2480 MHz
  • 16-bit analog outputs with adjustable gain

EMG SENSOR DATA ACQUISITION

  • 24-bit ADC
  • 0.3μV resolution for 0 to 5,000μV
  • 1.1μV resolution for 5,001 to 24,000μV
  • Selectable low-pass cutoff at 500/1000/1500 Hz
  • Selectable high-pass cutoff at 5/10/20 Hz
  • Selectable sample rate of 2000 or 4000 Hz

EMG PREAMPLIFIER

  • No notch (50/60 Hz) filters
  • Baseline noise: <1μV RMS
  • CMRR < -100dB
  • Input impedance: > 1,000 MΩ
  • Input range: +/- 24mV

SmartLeads

Sophisticated advances in technology resulted in the patent-pending “SmartLead” system,
which transforms the ESP device into an intelligent sensor for virtually any type of biometric
and physiological data, from any type of hardware.

Fine Wire Adapters

Fine Wire Adapters

Adapts standard snap connectors for use with fine wire electrodes.
Uses a coiled spring for making a connection to the fine wire.