About SEMG Products Applications Downloads News & Events Support & Training

FlexiForce®

FlexiForce

Localized Pressure Measurement
for Noraxon cable and telemetry systems

  • Measure pressure force between body
    and external surfaces, tools, machines
  • Very thin and flexible sensor construction
  • Available in three pressure ranges
  • Uses Standard Noraxon Plug-In Capability

The sensor manufactured by TekScan Inc., USA is a versatile, easy to use sensor for localized pressure. It can be used whenever pressure force between the human body, (e.g. hand, finger and foot) and any surface is investigated. The use of industrial tools, training machines, computer devices (PC mouse) or medical orthosis can be investigated together with EMG and other biomechanical sensors.

FlexiForce

Thin and flexible construction

The FlexiForce® sensor works on a resistive principle and is available in three pressure ranges and four lengths. It has a sensitive measurement area of 9.53 mm diameter and is very thin and flexible to conform to curved surfaces.

The sensor has a predefined measurement setup in all the Noraxon software packages and is operational in a few seconds:

Sensor Selection Screen

MyoResearch XP sensor selection screen

Application Examples

The sensor covers a variety of application areas in medical research, sports analysis, rehabilitation, ergonomics, and robotics. Due to the thin flexible shape, it can be mounted on fingertips, hand bones, toe, heel or any other prominent bony body area.

FlexiForce
FlexiForce

FlexiForce mounted to the heel, suitable for gait studies, impact testing jump and sports performance.

FlexiForce mounted to hand bones, allows detecting of hand and grip pressure force.

FlexiForce

FlexiForce mounted on a golf club. Measures the grip/swing force with golf stroke.

Specifications

Features:

  • Thin flexible sensor that is easily placed on a prominent bony body part
  • Useful in a variety of research areas includ-ing: Rehabilitation, Sports, Ergonomics and Robotics.

Typical Performance of sensor:

  • Linearity (Error): <± 5%
  • Repeatability: <± 2.5% of full scale
  • Hysteresis: < 4.5% of full scale
  • Response Time: < 5 μsec
  • Sensitivity (uncalibrated)
    - 0-1 lb sensor 5000 mV / lb (1135 mV/N)
    - 0-25 lb sensor 200 mV / lb ( 45 mV/N)
    - 0-100 lb sensor 50 mV / lb (11.4 mV/N)

Physical (sensor only):

  • Thickness: 0.008” (0.208mm)
  • Sensing Area Diameter: 0.375” (9.53mm)
  • Tail Length: 7.75” (197mm), 6” (152mm), 4” (102mm), 2” (51mm)
  • Width: 0.55” (14mm)

View Specs (PDF)