Product Overview
The TeleMyo™ Clinical Direct Transmission System (Clinical DTS) for EMG and other biomechanical sensors directly transmits data from the electrode or sensor site to a small USB receiver. This direct transmission concept greatly simplifies the arrangement of EMG measurements by eliminating the need to arrange cable connections between the EMG electrodes and EMG amplifier. The small light weight probes are also beneficial for small subjects like children and small animals. The Clinical DTS EMG signal is pre-processed using a 100ms RMS filter to give clinicians clean, easy-to-read signals.

The DTS system can operate any configuration between 2 and 8 channels (EMG is limited to 4 channels.) The default system is equipped with EMG preamplifiers but can be upgraded with other biomechanical sensors like goniometers, Inclinometers, and foot switches. A synchronization system can be used to accurately synchronize the TeleMyo Clinical DTS System to other biomechanical devices.
Unique Items
- Noraxon's superior signal quality
- Complete line of wireless biomechanical sensors
- Precise and flexible synchronization trigger system
- Easy installation: no drivers to install
- EMG signal is pre-processed and ready to use
Clinical DTS Probe and Receiver Specifications
Receiver Specifications
- Up to 8 sensor channels (only 4 can be used for EMG
sensors)
- USB connection to PC (no driver needed)
- 2 TTL 5V sync inputs
- External Antenna
Power Requirements
- Replaceable Li-ion rechargeable battery, operation time more than 8 hours after fully charged
Output & Transmission Frequency
(Depending on country)
- Up to 2.5 mW (depending on country allowance)
- DSSS 2403-2472 MHz on (up to) 20 selectable radio channels
- Clinical DTS Probe transmission range: 10m (typical)
EMG Sensor Data Acquisition System
- 16-bit resolution
- Initial Sample Rate 3000Hz
- 100ms RMS filter before wireless transmission
- Wireless update rate 100Hz
EMG Preamplifier Leads
- No notch (50/60 Hz) filters are used
- 1st order high-pass filters set to 10 Hz +/- 10% cutoff
- Baseline noise < 1 uV RMS
- Input impedance > 100 Mohm
- CMR > 100 dB
- Input range +/- 6.3 mV
- Base gain 200
- Final gain 500
- Snap-style or Pinch-style terminal electrode connections
Dimensions
- EMG Probes Dimensions: 1.34" L x 0.95" W x 0.55" H (3.4 cm x 2.4 cm x 1.4 cm)
- EMG Probes: Weight: Less than 14 g.
- Clinical DTS Receiver Dimensions: 3.0" L x 4.0" W x 1.4" H
(7.66 cm L x 10.18 cm W x 3.55 cm H)
- Clinical DTS Receiver Weight: Less than 120 g.